LIVE PRODUCTION
Angular Ladder Cable Tray — Cable Trays, manufactured by India Electricals Syndicate, Howrah
Cable Management Systems

Angular Ladder Cable Tray

Heavy-duty angle-section ladder trays for long unsupported spans.

MaterialIS:2062 Angle Sections
FinishHot-Dip Galvanized (85µ min., IS:2629)

Angular Ladder Cable Tray — Overview

The angular ladder cable tray from India Electricals Syndicate is built from rolled angle-section stringers to IS:2062 rather than formed sheet, giving the highest stiffness-to-span ratio in the IES cable management range. It is specified where support steel is widely spaced and the tray must carry heavy power cables over extended unsupported runs — power plant cable racks, refinery pipe bridges and offshore cable corridors.

Angle stringers are joined by welded rungs to carry sustained mechanical load with minimal mid-span deflection on unsupported spans up to 9 metres, reducing the number of supports, fasteners and site labour on long horizontal corridors. Stringer height and angle thickness are selected to the project cable loading and span schedule.

Fabrication and welding follow IS:2062 and IEC 61537 practice, hot-dip galvanized for long outdoor service life, with documentation supplied against specification. Manufactured at the Howrah works in continuous production since 1972. Share your span and loading schedule with a quote request and the engineering desk will respond with a documented offer.

Technical Specifications

Angular Ladder Cable Tray

Specifications

Stringer Section
50x50x6 — 100x100x10 angle
Width Range
150mm — 1200mm
Max Unsupported Span
9000mm
Material
IS:2062 E250A / E300A

Standards Compliance

  • IEC 61537
  • IS:12352
  • IS:2062

Materials Available

  • IS:2062 Angle Sections

Surface Finishes

  • Hot-Dip Galvanized (85µ min., IS:2629)

Applications

  • Power plants
  • Refineries
  • Heavy industrial cable corridors
  • Offshore platforms

Frequently Asked Questions

Why choose an angular ladder tray over a formed ladder tray?+

The rolled angle-section stringers give greater stiffness, so it carries heavy cable loads over longer unsupported spans (up to 9 metres) with fewer supports.

What is the maximum unsupported span?+

Up to 9 metres depending on cable loading; stringer height and angle thickness are selected to the project schedule.

Which standard governs the stringer material?+

Angle sections are to IS:2062, with cable tray practice to IEC 61537, hot-dip galvanized for outdoor service.

Where is it manufactured?+

At India Electricals Syndicate, Howrah, Kolkata — in continuous manufacture since 1972.

Testimonials

What specifiers say about IES cable trays

IES has been our specified cable tray and earthing vendor across multiple thermal projects. Documentation, MTC, and dispatch discipline have been consistent over years of supply.
[Procurement Lead Name]
Sr. Manager, Procurement
EPC contractor, thermal power project
Hot-dip galvanizing micron consistency and IS 12352 conformance on every batch — that's what we rely on for corrosive coastal sites. Lead times from Howrah are predictable.
[Project Engineer Name]
Project Engineer
Refinery project, eastern coast
For solar mounting structures across our 50 MW deployment, IES held the galvanizing spec across 30,000+ pieces. Quality dispute count: zero. That tells the story.
[Site Manager Name]
Site Manager
Solar IPP, western India

Names redacted pending NDA / consent. Real attribution available on request — speak with your IES sales contact.

Explore Where Angular Ladder Cable Tray Is Used

WhatsApp Us